LG Refrigerator Not Cooling but Freezer Works
When the freezer stays cold but the fridge section warms up, the usual cause is a frosted-over or blocked evaporator fan or air damper.
Short answer: A single click every so often, followed by the compressor humming normally, is just the start relay doing its job. Repeated clicking every few seconds without the compressor ever starting usually means the start relay or compressor itself is failing.
Timing the pattern is more useful than just listening for a click. A normal compressor cycle clicks once as it starts, and again, once, several minutes to hours later as it stops — long, quiet gaps in between are expected. A relay or compressor problem sounds rhythmic instead: a click every few seconds, repeating in a steady loop, with the compressor never actually settling into its usual hum. If you can count roughly how many seconds pass between clicks and whether that gap stays consistent, you'll know within a couple of minutes which pattern you're dealing with — no need to wait and see if the fridge eventually stops cooling to find out.
Time the clicking pattern
Listen for several minutes — a single click followed by a steady hum is the compressor starting normally. Repeated clicking every few seconds with no hum points to a start failure.
Check cooling performance
Confirm whether the fridge and freezer are still reaching normal temperatures — reduced cooling alongside clicking supports a relay or compressor issue.
Rule out ice-related fan noise
If accessible, check the freezer's rear panel for frost buildup that could be catching the evaporator fan (see our guide on cooling problems for a manual defrost procedure).
Have the relay tested if clicking is abnormal
A failing start relay is a relatively inexpensive, well-defined part — a technician can test and replace it without needing to touch the sealed refrigerant system.
1. Normal compressor start relay (single click)
A single click as the compressor starts or stops a normal cooling cycle is completely normal and not a fault — it's the relay engaging.
2. Failing start relay (repeated clicking)
If the relay repeatedly tries and fails to start the compressor, you'll hear a rhythmic clicking every few seconds without the compressor ever successfully starting.
3. Failing compressor
If the relay is fine but the compressor itself has a fault (seized or shorted windings), the relay will still repeatedly try and fail to start it, sounding similar to a relay issue.
4. Ice buildup against the evaporator fan
Less commonly, a clicking or ticking can come from a fan blade intermittently catching on ice buildup rather than the compressor circuit at all.
Yes — a single click as the compressor's start relay engages, followed by a quiet hum, is completely normal and happens every time the compressor cycles on.
In most cases yes — the start relay is a separate, inexpensive component. Only if the compressor itself has failed (not just the relay) would compressor replacement be needed, which is a bigger repair.
This distinction usually needs an appliance technician with testing equipment, since both produce a similar repeated-clicking symptom from the outside — don't assume which one it is before getting it checked.
Safety warning
Never attempt to service the sealed refrigerant system, compressor, or its electrical components yourself. If you smell burning or see scorch marks near the compressor, unplug the unit and contact a licensed technician.Home Solutions Editorial Team
Updated August 16, 2026. How we write guides
When the freezer stays cold but the fridge section warms up, the usual cause is a frosted-over or blocked evaporator fan or air damper.
Water pooling under or in front of a refrigerator almost always traces back to a clogged defrost drain or a water-line connection, not a coolant leak.
A GE ice maker that's stopped producing ice usually has a blocked water line, a freezer that's too warm, or the arm/switch turned off by accident.
If the display and buttons work but no water ever enters, the water supply valve behind the machine, a stuck float switch, or the inlet valve itself is almost always the cause.